The job
A cathedral that also works as a broadcast site needed a real network: segmented, redundant on the WAN side, and built around the internet handoff that was already there.
The design
- Firewall: Meraki MX250
- Switching: Meraki MS355
- Segmentation: multiple VLANs separating production, operations, and everything else
- WAN resilience: dual active-active 5G cellular gateways across both WAN paths, alongside the existing internet handoff
How the design changed
The 2024 design-phase plan specified an MX85. The final build used an MX250. Designs should move when the requirements get clearer, and this one did.
The install
I did the install with help from the Chief Engineer and Tech Ops. The memorable part was a 300-foot cable run through a three-foot crawl space under the church.
The cutover
The whole cutover happened in one overnight maintenance window. The facility ran production the next day.
Later
SD-WAN now connects this site to the main broadcast center.
What I’d tell the next person
- Let the design move. The plan said MX85 and the build used an MX250. That isn’t a failure of the plan. Requirements got clearer, so the design changed with them.
- One window means everything is staged first. An overnight cutover only works if every piece is built, labeled, and checked before the window opens.
- Physical work is part of network work. The crawl-space run was as important to this project as any config.
Still to add
Photos of the crawl-space run and the rack, and a simplified diagram with no addressing.